1.
Arq. bras. oftalmol ; 82(3): 189-194, May-June 2019. tab, graf
Article in English | LILACS | ID: biblio-1001312

ABSTRACT

ABSTRACT Purpose: The purpose of this study was to objectively assess the optical vision quality of patients before and after Nd:YAG capsulotomy for posterior capsular opacification using a double-pass retinal imaging system. Methods: We retrospectively analyzed the data from 26 pseudophakic eyes with posterior capsular opacification that underwent Nd:YAG capsulotomy. The objective scatter indices, modulation transfer function cutoff frequencies, Strehl ratios, and logMAR corrected distance visual acuities were assessed before and after YAG capsulotomy with a double-pass retinal imaging system (OQAS II, Visiometrics, Spain). We also analyzed data from a subgroup of 10 patients with pre-YAG corrected distance visual acuity of 0.10 logMAR (20/25) or better. Results: Vision quality indices improved in all 26 eyes, resulting in a statistically significant improvement in the corrected distance visual acuity (p=0.007), objective scatter index (p=0.001), modulation transfer function cutoff frequency (p=0.001), and Strehl ratio (p=0.020). The overall mean improvements included 0.12 ± 0.04 logMAR for corrected distance visual acuity, 2.84 ± 0.76 for objective scatter index, 12.29 ± 2.77 for modulation transfer function cutoff frequency, and 0.06 ± 0.03 for Strehl ratio. Our sub-analysis of 10 eyes with 0.10 logMAR (20/25) corrected distance visual acuity or better also showed a statistically significant improvement in the mean objective scatter index (0.76 ± 16; p=0.001), resulting in approximately 35% decrease in intraocular light scatter. Conclusions: The objective vision quality measurements as assessed by the double-pass retinal imaging system showed a significant improvement after YAG capsulotomy. This suggests that the objective scatter index improves after YAG capsulotomy, even in eyes with pre-YAG 0.10 logMAR (Snellen 20/25) corrected distance visual acuity or better.


RESUMO Objetivo: Avaliar objetivamente a qualidade da visão óptica antes e depois da capsulotomia com Nd: YAG, obtida por imagem pelo metodo de dupla passagem de luz em pacientes com opacificação capsular posterior. Método: Análise retrospectiva de 26 olhos pseudofácicos com opacificação capsular posterior visualmente significativa, que foram submetidos à capsulotomia de Nd: YAG. O índice de dispersão objetiva, a função de transferência de modulação, a relação de Strehl e a acuidade visual à distância corrigida foram avaliados antes e após a capsulotomia com YAG usando o dupla passagem de luz (OQAS II, Visiometrics, Espanha). Também foi analisado um subgrupo de pacientes com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (20/25) ou melhor. Resultados: Os índices de qualidade da visão melhoraram em todos os 26 olhos, resultando em uma melhora estatisticamente significativa na acuidade visual à distância corrigida (p=0,007), índice de dispersão objetiva (p=0,001), função de transferência de modulação (p=0,001) e relação de Strehl (p=0,020). A melhora média na acuidade visual à distância corrigida foi de 0,12 ± 0,04 logMAR, no índice de dispersão objetiva foi de 2,84 ± 0,76, no função de transferência de modulação foi de 12,29 ± 2,77 e na razão de Strehl foi de 0,06 ± 0,03 em todos os olhos. Sub-análise de 10 olhos com 0.10 logMAR (20/25) acuidade visual à distância corrigida ou melhor também mostrou uma melhora estatisticamente significativa no índice de dispersão objetiva (p=0,001). A melhora média no OSI foi de 0,76 ± 16, uma diminuição de 35% na dispersão da luz intraocular. Conclusões: A qualidade da visão avaliada pelo dupla passagem de luz mostra uma melhora significativa nas medidas objetivas da qualidade da visão após a capsulotomia do YAG. O índice de dispersão objetiva melhora após a capsulotomia YAG, mesmo em olhos com acuidade visual à distância corrigida pré-YAG de 0,10 logMAR (Snellen 20/25) ou melhor.


Subject(s)
Humans , Male , Female , Aged , Visual Acuity/physiology , Pseudophakia/physiopathology , Capsule Opacification/physiopathology , Posterior Capsulotomy/rehabilitation , Reference Values , Retina/physiopathology , Retina/diagnostic imaging , Retrospective Studies , Treatment Outcome , Pseudophakia/diagnostic imaging , Lasers, Solid-State/therapeutic use , Capsule Opacification/diagnostic imaging , Posterior Capsulotomy/methods
2.
Arq. bras. oftalmol ; 79(4): 255-257, July-Aug. 2016. graf
Article in English | LILACS | ID: lil-794585

ABSTRACT

ABSTRACT A 51-year-old patient underwent posterior vitrectomy with perfluoropropane gas injection, phacoemulsification, and implantation of an Oft Cryl® hydrophilic acrylic intraocular lens (IOL) because of traumatic retinal detachment and cataract in the right eye. On the first postoperative day, gas was filling the anterior chamber because of patient's non-compliance in terms of head positioning, and was reabsorbed within one week. Eight months later, the patient returned complaining of a significant decrease in vision. IOL opacification was noticed by slit-lamp examination. The lens was explanted to undergo gross and light microscopic analysis. The lens was also stained with the alizarin red method for calcium identification. Light microscopic analysis confirmed the presence of granular deposits, densely distributed in an overall circular pattern in the central part of the lens optic. The granules stained positive for calcium. This is the first case of the opacification of this type of hydrophilic lens. Surgeons should be aware of this potential postoperative complication, and the use of hydrophilic IOLs should be avoided in procedures involving intracameral gas because of the risk of IOL opacification.


RESUMO Uma paciente de 51 anos foi submetida à vitrectomia posterior com injeção de gás perfluoropropano, facoemulsificação e implante de lente intraocular (LIO) acrílica hidrofílica Oft cryl® devido a descolamento traumático da retina e catarata. No primeiro dia pós-operatório, o gás estava ocupando a câmara anterior pois a paciente não manteve o decúbito ventral restrito, tendo sido absorvido ao longo de uma semana. Oito meses depois, a paciente retornou com baixa da acuidade visual. Ao exame foi evidenciado opacificação da lente intraocular. A lente foi explantada e submetida à análise macroscópica e sob microscopia óptica. Também, foi corada pelo método de vermelho de alizarina, que identifica cálcio. A análise sob microscopia óptica evidenciou depósitos granulares, densamente distribuídos em padrão circular na parte central da óptica da lente intraocular, que coraram positivo para cálcio. Esse é o primeiro relato de opacificação dessa lente hidrofílica. Os cirurgiões devem estar atentos para esta potencial complicação pós-operatória.


Subject(s)
Humans , Female , Middle Aged , Postoperative Complications/etiology , Prosthesis Failure/etiology , Lens Implantation, Intraocular/adverse effects , Lenses, Intraocular/adverse effects , Vitrectomy , Phacoemulsification , Device Removal , Fluorocarbons , Microscopy/methods
3.
Arq. bras. oftalmol ; 77(4): 222-224, Jul-Aug/2014. graf
Article in English | LILACS | ID: lil-728663

ABSTRACT

Purpose: To evaluate the incidence of posterior capsule opacification (PCO) four years after the implantation of a hydrophilic acrylic intraocular lens (IOL). Methods: Fifty-eight randomly selected eyes from 58 patients were analyzed four years after phacoemulsification and Ioflex IOL implantation. The patients underwent an ophthalmic examination to detect PCO and a detailed medical history was obtained. The patients' charts were reviewed for their corrected distance visual acuity prior to the IOL implantation, as well as for one month postoperatively. The Student's t-test was used for statistical analysis. Results: The mean age of patients without PCO was 74.6 ± 9.5 years, compared to 70.3 ± 15 years in patients with PCO. Four years after surgery, 39 of the 58 eyes (67%) had detectable PCO and 24 eyes (41.3%) had decreased visual acuity (VA) due to PCO. These patients were referred for Nd:YAG laser capsulotomy. Three patients (5.1%) had decreased VA due to glaucoma, IOL opacification, or age-related macular degeneration. Twelve eyes (20.7%) presented mild PCO with unchanged VA. Systemic arterial hypertension was reported by 45% of the patients, and in 3.5% of these cases this was associated with diabetes mellitus. Conclusion: This study found the incidence of PCO to be 67% four years after phacoemulsification and Ioflex IOL implantation. .


Objetivo: Avaliar a incidência da opacificação da cápsula posterior com o implante de uma lente intraocular acrílica hidrofílica. Métodos: Cinquenta e oito olhos, de 58 pacientes, selecionados de forma aleatória, foram examinados 4 anos após a cirurgia de facoemulsificação com implante da lente intraocular Ioflex em uma campanha comunitária para pessoas carentes. Os pacientes foram submetidos ao exame oftalmológico a fim de detectar opacificação da cápsula posterior. Foi obtido histórico médico detalhado. A acuidade visual corrigida antes e 1 mês após a cirurgia foi obtida através de revisão em prontuário médico. O teste t de student foi utilizado para a análise estatística. Resultados: A idade média dos pacientes sem opacificação da cápsula posterior foi 74,6 ± 9,5 anos, e 70,3 ± 15 anos nos pacientes com opacificação da cápsula posterior. Após 4 anos da cirurgia, 39 olhos (67%) foram diagnosticados com opacificação da cápsula posterior, e 24 olhos (41,3%) tiveram redução da acuidade visual causada pela opacificação da cápsula posterior, sendo encaminhados para realização de capsulotomia com Nd:YAG laser. Três olhos (5,1%) tiveram redução da acuidade visual causada por glaucoma, opacificação da lente intraocular e degeneração macular relacionada á idade. Em outros 12 olhos (20,7%) que apresentaram opacificação da cápsula posterior, a acuidade visual ficou mantida. Dentre as doenças sistêmicas, a hipertensão arterial foi relatada por 45% da amostra avaliada e 3,5% referiram diabetes mellitus. Conclusão: O estudo encontrou incidência de 67% de opacificação da cápsula posterior na lente intraocular Ioflex 4 anos ...


Subject(s)
Aged , Female , Humans , Male , Acrylic Resins/adverse effects , Capsule Opacification/etiology , Cataract Extraction/adverse effects , Lens Implantation, Intraocular/adverse effects , Capsule Opacification/epidemiology , Follow-Up Studies , Incidence , Postoperative Complications , Visual Acuity